RAK WisMesh Tag
Ultra-kompakter GPS-Tracker auf nRF52840-Basis (WisBlock) in einer wasserabweisenden IP66-Hülle. 1000 mAh Akku, integrierter Beschleunigungssensor (ST LIS2DH), 4 Pogo-Pins für USB/DFU/Laden. Mehrfacher Tastendruck-Gesten-Bedienung (z.B. Doppeldruck = GPS-Ping). Kein Display. Ab Werk Meshtastic, MeshCore-Firmware unterstützt. Community-Firmware: Companion BLE/USB, Repeater, Room Server.
Hardware Spezifikationen
MCU
nRF52840
RAM
256 KB
Flash
1 MB
Display
-
Anzahl Tasten
1
LEDs vorhanden
ja
Gewicht
30 g
Abmessungen
60 x 40 x 12
LoRa Spezifikationen
Konnektivität
WLAN
nein
Bluetooth
ja
GPS
ja
Stromversorgung
USB-Typ
-
Akkuanschluss
Built-in LiPo 1000mAh
Solar-Unterstützung
nein
Stromverbrauch (Standby)
5 mA
Stromverbrauch (Senden)
82 mA
Firmware-Unterstützung
Release notes: https://blog.meshcore.io/2026/06/06/release-1-16-0
Release notes: https://blog.meshcore.io/2026/06/06/release-1-16-0
Release notes: https://blog.meshcore.io/2026/06/06/release-1-16-0
Release notes: https://blog.meshcore.io/2026/06/06/release-1-16-0
⚠️ Check that radio.rxgain(on) and flood.advert.base (0.308) are set correctly after flashing! ⚠️
This build is based on official MeshCore 1.15.0 dev branch (as of 25-May-2026 and additionally includes the following unmerged upstream PRs/changes:
- PR2553: Limit flood advert packet forwarding -->
set flood.advert.base 0...1(0: no flood adv. forwarding, 0.308: default, 1: all flood adv. forwarding) - PR1810: Allow direct message paths when denyf * is set
- :new: PR1727: Use hardware channel activity detection for checking interference --> Use
set int.thresh 1to activate hw based channel activity detection. - :new: PR2377: Disable NRF52 undervoltage bootlock feature
- Flood adverts are disabled (flood.advert.interval set to 0) by default
- :new: modified PR1810 to not block flood adverts but only
PAYLOADTYPEGRPTXTandPAYLOADTYPEGRPDATAso that some limited flood advert distribution can be managed via PR2553 to support e.g. observer maps.
- Based on
devv1.15.0 as of 25-May-2026
For beta testing, in progress...
Internal testing done. Beta testings with friends around the world. Flash Instruction: Download upgrade.bin to upgrade existing devices or freshInstall-merged.bin for new devices. Then Flash Custom Firmware.- Source code: https://github.com/IoTThinks/MeshCore/tree/PowerSaving-v16
- Repeaters and room servers for both ESP32 and NRF52: CLI
powersaving on - BLE companions for both ESP32 and NRF52: Enabled by default
- [NEW] Hibernate mode for ESP32 BLE Companions now work properly and at 16uA
- [NEW] Optimize Heltec T096 from 12mA down to 8.7mA
- [NEW] Repeaters for both ESP32 and NRF52: CLI
set reboot.interval <hours>. hours is 0-255. 0 is default and disabled. - [NEW] Set return path for repeaters: https://github.com/meshcore-dev/MeshCore/pull/2586
- [NEW] Add time keeping for NRF52 across resets: https://github.com/meshcore-dev/MeshCore/pull/2704
- FEM LNA for Heltec v4.3, Heltec T096, Heltec TrackerV2: CLI
set radio.fem.rxgain on/offhttps://github.com/meshcore-dev/MeshCore/pull/2140 - Automatically select I2C address (0x76 or 0x77) for BME280, BME680 and BMP680.
- Fixed boot loop for Xiao C6: https://github.com/meshcore-dev/MeshCore/pull/2570
- Check reset reasons for repeaters: CLI
powerlog - Check I2C and GPS GPIOs: for repeaters: CLI
sensor
- Heltec v4 bin files is for both Heltec v4.2 and v4.3
- Heltec v4.3 bin files is for Heltec v4.3 only
Found issues:
- BLE companions seem can not sleep at all due to new code in MeshCore 1.16. Wio Tracker L1 is at 35mA instead of 7.5mA as in PowerSaving 15. Will investigate and fix.
- CMDSENDRAW_PACKET errors accumulate memory:
For beta testing, in progress...
Internal testing done. Beta testings with friends around the world. Flash Instruction: Download upgrade.bin to upgrade existing devices or freshInstall-merged.bin for new devices. Then Flash Custom Firmware.- Source code: https://github.com/IoTThinks/MeshCore/tree/PowerSaving-v16
- Repeaters and room servers for both ESP32 and NRF52: CLI
powersaving on - BLE companions for both ESP32 and NRF52: Enabled by default
- [NEW] Hibernate mode for ESP32 BLE Companions now work properly and at 16uA
- [NEW] Optimize Heltec T096 from 12mA down to 8.7mA
- [NEW] Repeaters for both ESP32 and NRF52: CLI
set reboot.interval <hours>. hours is 0-255. 0 is default and disabled. - [NEW] Set return path for repeaters: https://github.com/meshcore-dev/MeshCore/pull/2586
- [NEW] Add time keeping for NRF52 across resets: https://github.com/meshcore-dev/MeshCore/pull/2704
- FEM LNA for Heltec v4.3, Heltec T096, Heltec TrackerV2: CLI
set radio.fem.rxgain on/offhttps://github.com/meshcore-dev/MeshCore/pull/2140 - Automatically select I2C address (0x76 or 0x77) for BME280, BME680 and BMP680.
- Fixed boot loop for Xiao C6: https://github.com/meshcore-dev/MeshCore/pull/2570
- Check reset reasons for repeaters: CLI
powerlog - Check I2C and GPS GPIOs: for repeaters: CLI
sensor
- Heltec v4 bin files is for both Heltec v4.2 and v4.3
- Heltec v4.3 bin files is for Heltec v4.3 only
Found issues:
- BLE companions seem can not sleep at all due to new code in MeshCore 1.16. Wio Tracker L1 is at 35mA instead of 7.5mA as in PowerSaving 15. Will investigate and fix.
- CMDSENDRAW_PACKET errors accumulate memory:
Based on MeshCore v1.14.1 plus the below features:
16 April 2026 -v14.1.1: Disabled NRF52POWERMANAGEMENT for RAK4631, RAK3401, Heltec T114, Xiao NRF52, Senscap Solar and Ga56230s meshkit and Ga56230s mesh tracker pro. 10 Arpril 2026 - v14.1.1: [BETA] Added Power saving for Heltec v3, v4.2 and v4.3 companion BLE. Reduced from 120mA down to 32mA for Heltec v3 and 39mA for Heltec v4. LNA and FEM LNA use default settings (E.g On). 09 April 2026 - v14.1.1: Fixed reset issue in high traffic locations for ESP32-based repeaters and room servers.NEW FEATURES:
Added Heltec v4.3 support: https://github.com/meshcore-dev/MeshCore/pull/1867. The PR will automatically detect Heltec v4.2 and v4.3. Added CLI control to LoRa's FEM LNA: https://github.com/meshcore-dev/MeshCore/pull/2140. Heltec T090 is not included. The details are below. Added CLI "powerlog" to list the last reset reason, last shutdown reason (NRF52 only) and last boot voltage (NRF52 only). This is to help debugging why the boards were reset due to software fault or low voltage (brownout).FEM LNA vs. Chip LNA:
FEM LNA is external LNA from the 1W boards (such as Heltec v4.3). You can on / off this FEM LNA: set/get radio.fem.rxgain on/off. This will impact the RX gain and power consumption (up to 7.8mA). When this is off, Heltec v4.3 can reach 5.8mA. For Heltec v4.2, this CLI will return "Not supported" as it does not support FEM control.
Chip LNA inside SX1262: This is available to all boards including 1W boards. You can on/off this LNA : set/get radio.rxgain on/off. This will impact the RX gain and power consumption (up to 0.5mA)
Repeaters and Room Servers:
Included latest PowerSaving and PowerSaving CLI (powersaving, powersaving on and powersaving off): 5.0mA for NRF52, 10mA for Heltec v3, 13mA for Heltec v4.2 and 5.5 mA for Heltec v4.3 (with FEM off). https://github.com/meshcore-dev/MeshCore/pull/1687
#### Companions:
[BETA] [ESP32] PowerSaving by default for Heltec v3 and v4. Reduced from 120mA down to 32mA for Heltec v3 and 39mA for Heltec v4.2 and 4.3.
Common features
Included sensor CLI to list I2C and UART GPIOs: sensor Kept date after crash/watchdog/brownout reset on ESP32: https://github.com/meshcore-dev/MeshCore/pull/1896 Automatically selected I2C address 0x76 and 0x77 for BME280/BME680/BMP280 Added i2c probe for sensors to start only in-use sensors: https://github.com/meshcore-dev/MeshCore/pull/1282 Added variant Xiao S3 (non-Wio) and Wio SX1262 (Initial support): SDA=D6, SCL=D7Instruction:
Please upgrade your easy to access devices first. Download: Download upgrade.bin to upgrade existing devices or freshInstall-merged.bin for new devices. Instruction to Flash Custom Firmware. Please read the instruction in Add sensors to repeaters Source code for PowerSaving 14Demo
Power Saving
Enter powersaving mode (CLI > powersaving on), 5.5mA for Heltec v4.3 with FEM and rxgain off, 5.8mA if FEM off and rxgain on. Thanks Wireless Rocks for your testing, . 13mA for Heltec v4.2 or Heltec V4.3 with FEM and rxgain on. 5.0mA for RAK4631<img height="384" alt="image" src="https://github.com/user-attachments/assets/be6e298d-4931-4e83-8220-0d072f8aeefd" />
<img height="384" alt="image" src="https://github.com/user-attachments/assets/924aa3a5-64d0-4112-aa66-6ff72178d3ac" />
<img height="384" alt="image" src="https://github.com/user-attachments/assets/903d899d-66c4-4d88-bf61-e9601797009f" />
Default PowerSaving for Heltec v3, v4.2 and v4.3 companion BLE. Reduced from 120mA down to 32mA for Heltec v3 and 39mA for Heltec v4.
<img height="384" alt="image" src="https://github.com/user-attachments/assets/73689821-61cc-4c3e-833f-1511632b71df" />
<img height="384" alt="image" src="https://github.com/user-attachments/assets/f9161bf7-8a95-4e7d-b26a-7a6cbe88a615" />
PowerLog CLI
Enter CLI "powerlog" to see last reset/shutdown reason and the battery voltage during last boot. <img height="384" alt="image" src="https://github.com/user-attachments/assets/79a31bf6-a0c2-46d3-bf7e-d63ca27e3014" /> <img height="384" alt="image" src="https://github.com/user-attachments/assets/1870c4e7-5942-466e-af0c-66e7567c7aae" />Sensor CLI
Enter CLI "sensor" to check I2C and GPS Serial pins <img height="384" alt="image" src="https://github.com/user-attachments/assets/060dd847-5984-4dc2-a5fe-cfe81180dc6c" /> <img height="384" alt="image" src="https://github.com/user-attachments/assets/49f25de7-a122-480f-a54a-a7176ec25f26" />Support and Discussion
If you want us to compile for your boards or have question, please comment in GITHUB or DISCORDLove the build?
- You may buy us a cofee ☕ for good work via Paypal  or Github .
v1.16_0607
- Companion UI: Native multilingual display on Heltec T096 (ST7735S)
Latin-based: Catalan, Croatian, Czech, Danish, Dutch, Estonian, Finnish, French, German, Hungarian, Icelandic, Italian, Latvian, Lithuanian, Maltese, Norwegian, Polish, Portuguese, Romanian, Slovak, Slovenian, Spanish, Swedish, Turkish, Vietnamese, Welsh
Cyrillic: Belarusian, Bulgarian, Macedonian, Russian, Serbian, Ukrainian
Greek: Greek
- Companion UI: Contacts screen now includes room servers; request telemetry from any contact.
[R]. Selecting any contact — chat node or room server — and long pressing opens an action menu: Send message or Request telemetry. Requesting telemetry displays the node's battery voltage and GPS coordinates (if present); long press to open the GPS Trace screen for that location.
GPS coordinates follow the Pos. Format selected in Settings (DD, UTM, or MGRS).
The message inbox group list now tags group/channel entries with [G] and room server entries with [R] for consistent visual distinction. Each room message shows the original author's name. When viewing a room message, long press to open the popup and select Reply to post back to the room (visible to all subscribers).
> Private room servers: messaging requires a prior login. Public rooms (no password) work without any login. For private rooms, log in once via the MeshCore app — if your account has admin rights on that room server, the session persists across reboots. Regular user sessions are not saved to flash and will require re-login after the room server reboots.
- Companion: switch the app connection between BLE and USB serial without reflashing.
usb build — the PC app connects over the USB serial port directly. Toggle via Settings → Connection Mode on the display, or via TerminalCLI: set conn.mode usb / set conn.mode ble. The setting persists across reboots. BLE toggle is hidden in the Settings menu while USB mode is active.
- Repeater, Room Sever: hold user button 5 seconds to power off.
- Repeater, Room Server:
advert.hops.maxdefault changed to 8; room server support added;flood.max.advertalias.
advert.hops.max now defaults to 8 instead of flood.max — advert relay limiting is active out of the box without any configuration. Room servers now also enforce this limit (previously repeater-only). The command flood.max.advert is accepted as an alias for compatibility with upstream firmware.
v1.16_0607
- Companion UI: Native multilingual display on Heltec T096 (ST7735S)
Latin-based: Catalan, Croatian, Czech, Danish, Dutch, Estonian, Finnish, French, German, Hungarian, Icelandic, Italian, Latvian, Lithuanian, Maltese, Norwegian, Polish, Portuguese, Romanian, Slovak, Slovenian, Spanish, Swedish, Turkish, Vietnamese, Welsh
Cyrillic: Belarusian, Bulgarian, Macedonian, Russian, Serbian, Ukrainian
Greek: Greek
- Companion UI: Contacts screen now includes room servers; request telemetry from any contact.
[R]. Selecting any contact — chat node or room server — and long pressing opens an action menu: Send message or Request telemetry. Requesting telemetry displays the node's battery voltage and GPS coordinates (if present); long press to open the GPS Trace screen for that location.
GPS coordinates follow the Pos. Format selected in Settings (DD, UTM, or MGRS).
The message inbox group list now tags group/channel entries with [G] and room server entries with [R] for consistent visual distinction. Each room message shows the original author's name. When viewing a room message, long press to open the popup and select Reply to post back to the room (visible to all subscribers).
> Private room servers: messaging requires a prior login. Public rooms (no password) work without any login. For private rooms, log in once via the MeshCore app — if your account has admin rights on that room server, the session persists across reboots. Regular user sessions are not saved to flash and will require re-login after the room server reboots.
- Companion: switch the app connection between BLE and USB serial without reflashing.
usb build — the PC app connects over the USB serial port directly. Toggle via Settings → Connection Mode on the display, or via TerminalCLI: set conn.mode usb / set conn.mode ble. The setting persists across reboots. BLE toggle is hidden in the Settings menu while USB mode is active.
- Repeater, Room Sever: hold user button 5 seconds to power off.
- Repeater, Room Server:
advert.hops.maxdefault changed to 8; room server support added;flood.max.advertalias.
advert.hops.max now defaults to 8 instead of flood.max — advert relay limiting is active out of the box without any configuration. Room servers now also enforce this limit (previously repeater-only). The command flood.max.advert is accepted as an alias for compatibility with upstream firmware.
v1.16_0607
- Companion UI: Native multilingual display on Heltec T096 (ST7735S)
Latin-based: Catalan, Croatian, Czech, Danish, Dutch, Estonian, Finnish, French, German, Hungarian, Icelandic, Italian, Latvian, Lithuanian, Maltese, Norwegian, Polish, Portuguese, Romanian, Slovak, Slovenian, Spanish, Swedish, Turkish, Vietnamese, Welsh
Cyrillic: Belarusian, Bulgarian, Macedonian, Russian, Serbian, Ukrainian
Greek: Greek
- Companion UI: Contacts screen now includes room servers; request telemetry from any contact.
[R]. Selecting any contact — chat node or room server — and long pressing opens an action menu: Send message or Request telemetry. Requesting telemetry displays the node's battery voltage and GPS coordinates (if present); long press to open the GPS Trace screen for that location.
GPS coordinates follow the Pos. Format selected in Settings (DD, UTM, or MGRS).
The message inbox group list now tags group/channel entries with [G] and room server entries with [R] for consistent visual distinction. Each room message shows the original author's name. When viewing a room message, long press to open the popup and select Reply to post back to the room (visible to all subscribers).
> Private room servers: messaging requires a prior login. Public rooms (no password) work without any login. For private rooms, log in once via the MeshCore app — if your account has admin rights on that room server, the session persists across reboots. Regular user sessions are not saved to flash and will require re-login after the room server reboots.
- Companion: switch the app connection between BLE and USB serial without reflashing.
usb build — the PC app connects over the USB serial port directly. Toggle via Settings → Connection Mode on the display, or via TerminalCLI: set conn.mode usb / set conn.mode ble. The setting persists across reboots. BLE toggle is hidden in the Settings menu while USB mode is active.
- Repeater, Room Sever: hold user button 5 seconds to power off.
- Repeater, Room Server:
advert.hops.maxdefault changed to 8; room server support added;flood.max.advertalias.
advert.hops.max now defaults to 8 instead of flood.max — advert relay limiting is active out of the box without any configuration. Room servers now also enforce this limit (previously repeater-only). The command flood.max.advert is accepted as an alias for compatibility with upstream firmware.
Full Changelog: https://github.com/MichTronics/MeshCoreNG/compare/bridge-tcp-v1.0.5...repeater-v1.0.1
Full Changelog: https://github.com/MichTronics/MeshCoreNG/compare/bridge-tcp-v1.0.5...companion-v1.0.1
Full Changelog: https://github.com/MichTronics/MeshCoreNG/compare/bridge-tcp-v1.0.5...companion-v1.0.1
Full Changelog: https://github.com/MichTronics/MeshCoreNG/compare/bridge-tcp-v1.0.5...room-server-v1.0.1
Automatischer Sync von verschiedenen Repositories
Links
Kauflinks
https://store.rakwireless.com/products/rak10701-wismesh-tag
https://store.rokland.com/products/wismesh-tag-from-rakwireless-mokosmart-meshtastic-compatible-card-sized-node-us915-mhz
Kauflinks zu Online Shops können sich ändern. Es wird keine Garantie über deren Erreichbarkeit übernommen.